    Understanding Sensor Health-Check Alerts: Offline & IN/OUT Discrepancy

    Overview

    Vemcount automatically sends health-check email alerts when sensors go offline or when the difference between IN and OUT counts exceeds a configured threshold (commonly ±5% or ±10%). This article explains what these alerts mean, how to read them, and what action to take.


    Types of Automated Alerts

    1. Sensor Offline Alert

    Triggered when a sensor has not communicated with the Vemcount platform for 2 or more hours.

    What the alert contains:

    • Location name

    • Sensor name and ID

    • Last seen timestamp

    • IP address and MAC address

    Immediate steps:

    • Check whether the sensor's network connection is active (ethernet cable, switch port, router).

    • Power-cycle the sensor — a reboot resolves most temporary offline states.

    • Verify the IP address shown in the alert is still reachable on the local network.

    • If the sensor remains offline after a reboot, contact support with the sensor ID and last seen timestamp.

    2. IN/OUT Discrepancy Alert (±5% or ±10%)

    Triggered when the difference between people entering (IN) and people exiting (OUT) exceeds the configured threshold over a given period.

    Example alert content:

    • Location and sensor ID

    • Percentage difference between IN and OUT counts

    • Today's total sum (IN and OUT values)


    Understanding IN/OUT Discrepancy

    A perfect IN/OUT balance (0% difference) is rarely achievable in real-world environments. The following are normal:

    • Small variances (under 5%) — typically within normal sensor behaviour, especially at high-traffic locations.

    • Moderate variances (5–15%) — may indicate sensor positioning drift, a partially obstructed field of view, or a very low total count (where one extra person creates a large percentage swing).

    • Large variances (15%+) — warrant investigation. Common causes include a miscalibrated counting line, a sensor in rescue/error mode, or a counting line that partially overlaps an area counted by another sensor.

    Common Causes of High IN/OUT Difference

    • Counting line covers an area also visible from the outside (passers-by counted as entries)

    • Sensor has been physically repositioned since last calibration

    • Very low traffic volumes (e.g. 1 IN, 0 OUT = 100% difference — not statistically meaningful)

    • Sensor in rescue mode or experiencing a firmware issue

    • Dual-entrance configuration where one sensor is offline


    When to Contact Support

    You do not need to contact support for every health-check alert. Reach out if:

    • A sensor remains offline for more than 24 hours despite a reboot and connectivity check.

    • The IN/OUT discrepancy persists above 15% for more than 2–3 consecutive days.

    • The discrepancy started suddenly following a physical change at the entrance (renovation, door repositioning, new display unit).

    • You suspect the data quality is affecting your footfall reporting.

    When contacting support, include the location URL from Vemcount and the date range showing the issue.