    Purpose: This guide outlines the outbound firewall and network access required for TDI sensors to communicate correctly with Vemcount services.

    Important: All firewall rules should be configured for outbound connections only. DNS resolution for the listed hostnames should also be allowed.

    Required network access

    Service

    Hostname / URL

    Port(s)

    Purpose

    Data push (HTTP)

    data.vemcount.com/ss/tdi

    80

    Transmission of sensor data to Vemcount using HTTP push

    Data push (HTTPS)

    data.vemcount.com/ss/tdi

    443

    Transmission of sensor data to Vemcount using HTTPS push

    Time synchronization

    ntp.vemcount.com

    123/UDP

    Time sync for stable and accurate operation

    License validation

    license.vemcogroup.com

    443

    License checks and validation

    TDI setup note: In the official TDI integration guide, Vemcount specifies Server Address:data.vemcount.com, Server Directory:/ss/tdi, and port 80 for HTTP or 443 for HTTPS. The guide also recommends using XML instead of JSON if special characters or spaces may cause push-format issues.

    Additional setup notes

    • In the TDI sensor, go to Server Config and enter the Vemcount server details.

    • Use the sensor's Test Setting function to confirm that the push connection works.

    • If JSON formatting causes issues, switch to XML as recommended in the official guide.

    Main Vemcount IP addresses

    • 18.195.189.44

    • 15.197.146.64

    • 3.33.145.212