Serach Icon

    Brickstream Sensors - Vemcount Firewall Guide

    Brickstream Sensors - Vemcount Firewall Guide

    Purpose: This guide outlines the outbound firewall and network access required for Brickstream sensors to communicate correctly with Vemcount services.

    Important: All firewall rules should be configured for outbound connections only. DNS resolution for the listed hostnames should also be allowed.

    Required network access

    Service

    Hostname / URL

    Port(s)

    Purpose

    Device administration / remote connection

    brickstream.vemcount.com

    3000

    Remote access and administration of Brickstream sensors

    Data push

    data.vemcount.com

    80, 443

    Transmission of sensor data to Vemcount

    Time synchronization

    ntp.vemcount.com

    123/UDP

    Time sync for stable and accurate operation

    License validation

    license.vemcogroup.com

    443

    License checks and validation

    Optional / legacy note: The official Vemcount firewall guideline also lists port 440 for older devices that cannot handle TLS above v1.0, plus additional services such as MQTT, FTP upload, VPN, and other device-specific endpoints. These are normally not required for a standard Brickstream setup unless specifically requested.

    Main Vemcount IP addresses

    • 18.195.189.44

    • 15.197.146.64

    • 3.33.145.212

    Brickstream / Vemcount network requirements

    Use the required outbound rules above when configuring network access for Brickstream sensors in a standard Vemcount setup.

    clock

    7PM

    GMT+2

    clock

    7PM

    GMT+2

    clock

    7PM

    GMT+2

    Become Our Supplier Or Partner