Xovis — sensor troubleshooting guide
This guide covers how to diagnose and resolve the most common Xovis sensor issues — LED states, tracking quality problems, sensor recovery, and when to initiate an RMA. Source: Xovis Knowledge Base.
Sensor LED states
All PC-Series sensors have a front LED that shows the device state. The LED can be hidden by rotating the cover 180°. Default setting: LED On. Can be toggled via the REST API.
Solid green | Normal operation — connected to network and remote server |
Blinking green | No connection to a remote server, but network/DHCP is OK |
Blinking orange/amber | No network connection (no DHCP lease, no Ethernet link) |
Blinking red | Rescue mode / hardware reset in progress |
Solid red | Critical error — sensor needs attention |
FW5 network test order: (1) check connection to remote server (HUB/support/iot.xovis.com), (2) check for DHCP or static IP, (3) check Ethernet/WiFi link. If all checks fail, LED continues blinking green.
Tracking quality issues — diagnostics
Navigate to Tools → Diagnostics in the sensor WebUI
Enable Connect to diagnostics server (recommended over downloading the file)
Lens check
Go to Diagnostics → Lens check. Both left and right lenses should have equal brightness and sharpness. Common problems:
Completely dark lens | Dust cap not removed after installation — remove it |
Shadow on one side | Sensor cover not clicked on correctly — reseat the cover |
Blurry/dirty right lens | Condensation, high humidity, or water contact — clean and dry the lens |
Pixelated edges | Sensor tilt needs adjustment — does not affect counting accuracy |
Stereo image (PC-Series only)
The stereo image shows the height profile of the scene. The floor should appear as a homogeneous blue area. If it is not:
Non-uniform floor colour | Redraw floor mask and apply recalibration |
Aluminium rilled carpet causing bubbles | Increase the |
Illumination issues
If certain areas are too dark or too bright and causing tracking problems, use Illumination masks in Settings → Singlesensor → Image setup. This prevents the sensor from basing its exposure on those areas.
Mask a bright area → sensor brightens the rest of the image |
Mask a dark area → sensor dims the rest of the image |
Unwanted tracking bubbles in specific areas
Add an Exclusion mask in Scene Configuration to suppress tracking in that area. Available for single sensors and multisensors (since FW5).
PF-Series manual recalibration
Go to Tools → Depth image. The floor should be visible as a blue area.
If not: open the Recalibration tool (bottom-left corner)
Select the floor → triggers a new calibration calculation
Apply the new calibration and verify the depth image has improved
Recovering a sensor that can't be reached on the network
With hardware reset button (PC2SE, PC2RE, PC2S, PC2R, PF-Series)
Power-cycle the sensor OR trigger a reboot via the API
While the sensor is booting up, press and hold the hardware RESET button for at least 10 seconds
The sensor will flash red to confirm the reset was accepted
The sensor resets only the network settings (DHCP re-enabled, fallback IP restored) and starts in rescue mode
Connect to the sensor on its fallback IP (
192.168.1.168)
Without hardware reset button (older sensors)
Set your computer's IP to
192.168.1.150(same subnet)Download and run Xovis Sensor Explorer from the Xovis Downloads section
Go to Menu → Set temporary IP (FW5.x) → set IP to
192.168.1.168After ~20 seconds, the sensor is reachable at
192.168.1.168These IP settings are temporary — the sensor reverts to its previous IP on next reboot unless you save the new settings
Also try: https://192.168.1.168/rescue or http://192.168.1.168/rescue in your browser. For legacy FW3.x/4.x sensors: 192.168.1.168:8080.
When to start an RMA
If the sensor is still not accessible after the recovery steps above, open an RMA ticket at support.xovis.com. Include the sensor MAC address, firmware version (if known), and a description of what was tried.
Multisensor-specific issues
Double bubbles / duplicate tracks | Bad stitching. On single sensor level: check mounting height, floor mask, and recalibration. On multisensor level: restitch the problem sensors with reference points in a large triangle. |
Hole in tracking area | Obstacle blocking sensor view, or gap between sensor coverage areas. Use Path Stitcher to bridge the gap. |
Jumping bubbles | Time sync issue — check that all sensors use the same NTP server and can reach it. Check logs for network/firewall issues. |
Unwanted bubbles in one area | Add an exclusion mask at the multisensor level. |
Overall tracking not satisfying | Try Tracker Mode V3 in Advanced options → Tracking version, then enable it on individual sensors. |
Getting help from Xovis
Submit a support ticket at support.xovis.com. Enable Support Mode in the Xovis HUB (Hub → your avatar → Support) to give Xovis remote access to your sensor fleet — all support actions are logged in your audit trail.
7PM
GMT+2
7PM
GMT+2
7PM
GMT+2
Who We Are
Aliquam Dui Diam, Tincidunt Eget Nulla Eget, Dictum Feugiat Felis. Cras Mattis Eget Tellus Quis Fringilla. Morbi Molestie Enim
Sed dictum ligula luctus intum Vivamus.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Lorem ipsum dolor
Sed quis massa leo. Quisque tristique tellus sit amet arcu tempor ultrices. Nulla ullamcorper.
Become Our Supplier Or Partner
Mauris tempor libero massa, at vulputate velit aliquet eget. Fusce et tortor ex. Nullam venenatis, quam vel blandit molestie.